Input Voltage - 100∼120Vac, 50/60Hz or 220∼240Vac, 50/60Hz.
Output rating - Relay’s
contact rating current: 10Amp/250Vac(p.f=1).
Operating Temperature - 0∼50℃; 10∼90%.
CONTROL FEATURE
Provide
operating modes of Fan only、Dry、Cool、Heat and Fuzzy. Provide evaporator fan speed of Low、Med、High and Auto. Provide Sleep function for temperature set point to be automatic increased or decreased when Cooling or Heating operation. Provide the air discharge sweep in vertical direction via DC step motor controls for different rotation as per each mode. Provide the air discharge swing in horizontal direction via AC synchronous motor On/Off controls. Temperature set point for a range of 16〜30℃or 61〜86℉. Provide current time clock display and a program timer for unit Time-On or Time-Off settings. Three sensors for temperature detection of return air’s, Evaporator coil’s and Condenser coil’s. Provide Compressor Restart delay 3 minutes; and a 90 second delay for Rev. Valve protection. Provide anti-freeze function during cooling operation; and De-Icing function for Heat-Pump mode