MCL302

Miconair LCD TYPE WIRELESS CONTROLLER

SPECIFICATION

Main Board MCL302-MB

*PCB layout and dimensions

could be specified

 

LCD wireless hand-set

IR-CL302(Closed)

 

LCD wireless hand-set

 IR-CL302(Opened)

Input Voltage -  100120Vac, 50/60Hz or 220240Vac, 50/60Hz.

Output rating -  Relay’s contact rating current: 10Amp/250Vac(p.f=1).

Operating Temperature - 050; 1090.

 

CONTROL FEATURE

Provide operating modes of Fan onlyDryCoolHeat and Fuzzy.

Provide evaporator fan speed of LowMedHigh and Auto.

Provide Sleep function for temperature set point to be automatic increased or decreased when Cooling or Heating operation.

Provide the air discharge sweep in vertical direction via DC step motor controls for different rotation as per each mode.

Temperature set point for a range of 1630or 6186.

Provide current time clock display and a program timer for unit Time-On or Time-Off settings.

Three sensors for temperature detection of return air’s, Evaporator coil’s and Condenser coil’s.

Provide Compressor Restart delay 3 minutes; and a 90 second delay for Rev. Valve protection.

Provide anti-freeze function during cooling operation; and De-Icing function for Heat-Pump mode.

Provide Auto restart function in case of once power failure, it is able to remain all the last settings and automatic to restart operation upon the power input returned.

Provide optional pump motor controls for unit which needs to drain condensed water by an external pump equipment. And also, attach water full detecting from a floating switch.

 

WIRING DIAGRAM