MCL302
Miconair LCD TYPE WIRELESS CONTROLLER
SPECIFICATION
Input Voltage - 100∼120Vac, 50/60Hz or 220∼240Vac, 50/60Hz.
Output rating - Relay’s
contact rating current: 10Amp/250Vac(p.f=1).
Operating Temperature - 0∼50℃; 10∼90%.
CONTROL FEATURE Provide operating modes of Fan only、Dry、Cool、Heat and Fuzzy. Provide evaporator fan speed of Low、Med、High and Auto. Provide Sleep function for temperature set point to be automatic increased or decreased when Cooling or Heating operation. Provide the air discharge sweep in vertical direction via DC step motor controls for different rotation as per each mode. Temperature set point for a range of 16〜30℃or 61〜86℉. Provide current time clock display and a program timer for unit Time-On or Time-Off settings. Three sensors for temperature detection of return air’s, Evaporator coil’s and Condenser coil’s. Provide Compressor Restart delay 3 minutes; and a 90 second delay for Rev. Valve protection. Provide anti-freeze function during cooling operation; and De-Icing function for Heat-Pump mode. Provide Auto restart function in case of once power failure, it is able to remain all the last settings and automatic to restart operation upon the power input returned. Provide optional pump motor controls for unit which needs to drain condensed water by an external pump equipment. And also, attach water full detecting from a floating switch.
WIRING DIAGRAM
|